< Instrument(HK)Co.,Ltd.
 
Laboratory
Medical electronic product
Medical Consumables
Newborn Unit
Medical Instrument
Detal Instrument
Anaesthsia system
Hospital Furniture
Medical Equipment
Medical Ultrasonic Nebulizer
Reverse osmosis water treatment systems
Exibition
Medica 2013  
MEDICAL FAIR THAILAND 201  
FIME 2013  
Medicall Expo India 2013/  
69th CMEF 2013(Spring)  
 
 
Products

 
 
  
Infant-radiant-warmer
 

Infant-radiant-warmer

BN—100 (Top grade) infant radiant warmer
Brief introduction:
☆Microprocessor based servo controlled
  temperature system.
☆The microprocessor-controlled unit allows for
  three settings: pre-warm, manual or automatic.
☆Alarm functions for safety includes:
   Power failure;
   Temperature deviation;
   Temperature sensor failure;
   over temperature;
☆APGAR timer to record therapy time
☆Convenient X-ray cassette under infant bed
☆Heater head can be adjusted  + 90º horizontally
☆Tilt angle of infant bed is adjustable
☆Observe light angle is adjustable
☆Transparent protector folded
☆Adopts anti-explosion micro crystal quartz infrared
  radiation tube for its radiation source,the heating
  is quick and life-span is long
☆Alarms are audible and visual
☆A second thermal cut-out function for more safety
☆Skin temperature sensor failure protect function
  avoid over temperature
☆Temperature deviation can be amended in front
  panel directly
☆Low pressure aspirator, oxygen supply system
  and LED phototherapy unit

 Technical data:                 
 1.Power supply : 110/220V   60/50Hz
 2.  Power input: ≤1200VA
 3. Operating condition:
    An ambient Temperature:18℃-30℃
    An ambient Relative Humidity: 30%--75%RH
    Atmospheric Pressure: 700~1060 hPa
    An ambient Air Velocity <0.3m/s
 4. Temperature control: 32℃~38℃
 5.Temperature control accuracy: ≤0.5℃
 6.Mattress temperature uniformity : <2℃
 7.Skin temperature sensor accuracy: + 0.3℃
 8.Warm-up time: ≤30min
 9. Infant Bed tilt angle:+ 10°
 10.APGAR timer range: ≤24h
 11.Heater head horizontal: ±90°
 12.Mattress size: 67cm× 54cm
 13.Distance from heater to mattress:80cm
 14.Height adjustable range:0-20cm
 15.LED phototherapy light: 2pcs × 8W

Standard configuration:
 Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette , Observe light , I.V.pole, skin temperature sensor, tray, mattress, transparent protector, castors.
LED phototherapy unit ,low pressure aspirator; oxygen supply system.

Optional parts:
  Drawer,;
  RS-232(485) connector;

Transport and storage:
 Environment Temperature:-40℃~ +55℃
 Environment Relative Humidity: ≤95%
 Atmospheric Pressure: 500~1060hPa

Package:
 Each unit is packed one case
  Size:135cm×85cm × 98cm
  Gross weight: ≤170kg

 
4/F, Block 210, 2nd Industrial Area of Nanyou, Nanshan Dist., Shenzhen, P.R.China TEL:+86-755-26713783   26713784
粤ICP备05013543号 Copyright-2001-2010 BESTMAN Inc. All rights reserved. 深圳网站建设